冷却塔在数据中心领域确实具备极高的应用潜力,是当前算力基础设施绿色升级的核心散热方向之一。
- 市场增长空间广阔
2024年全球数据中心用冷却塔市场规模已达34.71亿美元,预计2024-2031年将以10.9%的年复合增长率攀升至67.75亿美元,远超冷却塔行业整体6.39%的增速,是驱动行业扩容的核心动力。全球每年稳定新增130-140个超大规模数据中心,直接拉动高性能冷却塔的刚性需求。 - 技术适配性持续升级
闭式、干湿式等新型冷却塔可适配AI算力机房的高要求:全密闭循环保障冷却水洁净,避免管路结垢腐蚀,设备寿命可达15年以上;相比传统开式塔节水60%以上,搭配变频Fan可降低20%以上的散热能耗,部分项目实测年总节能率接近47%。 - 场景覆盖不断延伸
冷却塔不仅是常规风冷/水冷数据中心的核心散热设备,更是液冷系统的最终热量排放枢纽,直接决定冷板式、浸没式液冷的整体散热效率,适配高密算力机柜的散热需求,完全契合数据中心PUE≤1.4的绿色发展目标。
Written by: Zhongliang Yiji Technical Department · 15 Years of Cooling Tower Selection Experience | Last Updated:2026-10-16
FAQ
How to choose between a closed-circuit and an open cooling tower?
For working conditions that demand clean water (such as vacuum furnaces, high-frequency furnaces, and injection machine hydraulic oil cooling), a closed-circuit tower is preferred: the cooled medium circulates inside the coil without direct contact with air, so it resists scaling, algae and particle contamination, with stable heat transfer and low maintenance. For ordinary recirculating water scenarios with tight water budgets or cost sensitivity, an open tower costs less upfront but requires supporting water treatment.
What are the footprint and connections of a 100 t closed-circuit cooling tower?
Taking a standard 100 m3/h closed-circuit tower as an example: overall dimensions are approximately 3500 x 1500 x 2800 mm with a footprint of about 5.25 m2; inlet and outlet piping is typically DN100, with a 5-10 C temperature drop under standard conditions. Refer to the product specification table for details; non-standard dimensions can be customised on site.
How do I size the pump and head for a cooling tower?
Pump flow is selected according to the rated circulating water volume of the cooling tower; head must account for pipeline friction losses, local resistance, equipment elevation difference and the necessary margin. Pressure-bearing equipment such as injection machines also requires reserve for the working pressure. It is recommended to hand the operating data (flow, temperature difference, installation height, pipe diameter and length) to technical staff for calculation, to avoid an undersized pump or excessive head that wastes energy.
What water treatment does a closed-circuit cooling tower need?
The outer circulating water of a closed-circuit tower still contacts air, so softened make-up water, periodic corrosion and scale inhibitor dosing, and control of the concentration ratio are recommended. The inner circulating medium should be softened water, antifreeze or pure water according to process requirements; outdoor installation in winter requires freeze protection (electric tracing or draining).